The battery sensor in #3565 (applesmc TB0T) needs an alert without a custom-metrics script. The agent now reports every lm-sensors input with a stable key, so a threshold can name one sensor. A native temperature sensor raises an alert only when its own override sets one: Overrides["agent:<host>/sensor:<hex>"].Temperature, where <hex> is the lower-case hex of the sensor ID, so IDs that differ only by case stay apart after host child IDs are lower-cased. There is no default and nothing is inherited from the host's or a linked node's CPU temperature. Evaluation uses the canonical metric path (metric temperature, resource type agent-sensor, now a spec bridge type), so delays, escalation, quiet hours and notifications behave as for other temperatures. The report carries no completeness state yet, so an invalid reading, a missing sensor, an empty inventory or telemetry expiry hold a firing alert instead of resolving it; the existing 24-hour stale sweep still applies. Removing or disabling the override, host or agent alerting off, host removal and a confirmed offline host resolve it. Config saves re-judge it by its own threshold and drop pending runs whose policy the save switched off, using the host link identity recorded with the run. Alert history joins the machine, and Patrol never auto-resolves these alerts because its snapshot holds no sensor reading. No UI writes these overrides yet; the Thresholds section follows. Refs #3565