rcourtman d87938bb24 Keep PBS job alerts through outages and partial reads
A PBS outage removed the datastore from a poll and stored the instance
without job results, so every failed-job alert cleared and fired again
when PBS returned. Job incidents now need two polls that see success
before recovering, so a missing datastore reads as unknown, and a failed
poll keeps the last job results so the carry survives the outage.

Only a failed job-list read now makes a family unreadable; task-history
trouble no longer keeps a removed job's failure alive. Recovery is judged
from the run's own status, so a success first seen after its next
schedule passed still clears the carry. Carried failures stay in memory:
a restart forgets them until PBS reports the job again.