Jonas Bark 0db8cf0c31 Keep the device registered on in-place "No connection" disconnect
The "No connection" picker entry disconnects without leaving the details
page, but Connection.disconnect(forget: false) removed the ProxyDevice
from the registry (isResetting is false). The open page kept the now
orphaned object: rediscovery built a *new* ProxyDevice while the page
still pointed at the old one, so selecting Virtual Shifting again
reconnected a device absent from bluetoothDevices — its BLE notifications
were rejected ("Device not found") and the connection was force-dropped.

Add a keepInList flag to disconnect; the in-place "No connection" path
passes it so the same device object stays registered (and its scan
result is retained to avoid a churned duplicate) and remains
reconnectable on the same card. The Disconnect buttons, which pop the
page, keep the default removing behaviour.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>