mirror of
https://github.com/rcourtman/Pulse.git
synced 2026-11-29 09:10:58 +01:00
Per-sensor alerts, history and a CPU-source choice (#3565) need to name one hardware input reliably, and the existing flat maps cannot: their keys drop the chip's bus address and lower-case the label, so two NVMe drives, two CPU sockets or applesmc's TC1F/TC1f collapse into one reading, and readings outside 0-150 °C vanish. The agent now also reports sensors.native: one entry per tempN_input and fanN_input of every chip, keyed "<chip>/<channel>", with the original label, kind, unit, unconverted value and an ok/invalid status. Implausible readings such as applesmc's -127 °C stay listed as invalid rather than disappearing, a stopped fan's 0 RPM is a reading, and a chip whose inputs leave the legacy maps empty still reports. The list is sorted, deduplicated and bounded at 256 entries; cluster peer results leave it out. Ingest accepts an entry only when its ID is exactly <chip>/<channel> for a canonical channel of the reported kind, derives the unit, and recomputes the status with the same shared plausibility policy, so the server does not depend on the agent's judgement. The inventory is carried through the host model, frontend state, unified resources, clones and the read-state projection. Nothing consumes it yet. The legacy maps keep their keys, filters and consumers. The contract notes record what later slices must add first: completeness state before a missing entry can mean a removed sensor, and a collision-free encoding before the ID becomes a lower-cased alert or metric key. Refs #3565