Files
Pulse/internal/monitoring/host_agent_temps_test.go
rcourtman 4f14ad6ab9 Use one primary CPU temperature rule everywhere
Three rules chose a node's single CPU temperature. Node history took
CPUMax first, agent history took cpu_package first, and the node drawer
recomputed the maximum of package, CPUMax and every core in the
browser. On an agent-fed node CPUMax is built from cores alone and can
sit below the package, and elsewhere a core can run above the package,
so the drawer's CPU temperature headline could disagree with the line
drawn beneath it and with the History tab. Node alerts and the CPU
low/record tracking used yet another package-first rule.

models.PrimaryCPUTemperatureCelsius is now the one rule: the hottest
usable package, CPU-maximum or core reading, with a sensor-map form for
agents. Node and agent history, the router's live fallbacks, the
unified resource temperature, node temperature alerts and the CPU
low/record tracking all call it. The drawer reads the resource value
through a new Node.cpuTemperature field instead of recomputing it, and
getCpuTemperature is removed.

Mock mode wrote a second package reading under a cpu.package key into
every agent host, including node-linked ones, from a series unrelated
to the node's static reading. A node and its linked agent now carry one
reading, sampled from the agent's series under the agent's real keys,
and both histories seed from that series, so the current reading
continues the line.
2026-10-13 20:15:36 +01:00

883 lines
28 KiB
Go

package monitoring
import (
"context"
"testing"
"time"
"github.com/rcourtman/pulse-go-rewrite/internal/config"
"github.com/rcourtman/pulse-go-rewrite/internal/models"
unifiedresources "github.com/rcourtman/pulse-go-rewrite/internal/unifiedresources"
agentshost "github.com/rcourtman/pulse-go-rewrite/pkg/agents/host"
"github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"
"github.com/stretchr/testify/assert"
)
func TestConvertHostSensorsToTemperature_Empty(t *testing.T) {
sensors := models.HostSensorSummary{}
result := convertHostSensorsToTemperature(sensors, time.Now())
if result != nil {
t.Error("expected nil for empty sensors")
}
}
func TestConvertHostSensorsToTemperature_CPUOnly(t *testing.T) {
sensors := models.HostSensorSummary{
TemperatureCelsius: map[string]float64{
"cpu_package": 55.0,
"cpu_core_0": 50.0,
"cpu_core_1": 52.0,
},
}
now := time.Now()
result := convertHostSensorsToTemperature(sensors, now)
if result == nil {
t.Fatal("expected non-nil result")
}
if !result.Available {
t.Error("expected Available to be true")
}
if !result.HasCPU {
t.Error("expected HasCPU to be true")
}
if result.CPUPackage != 55.0 {
t.Errorf("expected CPUPackage 55.0, got %f", result.CPUPackage)
}
if len(result.Cores) != 2 {
t.Errorf("expected 2 cores, got %d", len(result.Cores))
}
// Cores should be sorted
if result.Cores[0].Core != 0 || result.Cores[1].Core != 1 {
t.Error("cores not sorted correctly")
}
if result.CPUMax != 52.0 { // Max of core temps
t.Errorf("expected CPUMax 52.0, got %f", result.CPUMax)
}
}
func TestConvertHostSensorsToTemperature_NVMe(t *testing.T) {
sensors := models.HostSensorSummary{
TemperatureCelsius: map[string]float64{
"cpu_package": 45.0,
"nvme0": 40.0,
"nvme1": 42.0,
},
}
result := convertHostSensorsToTemperature(sensors, time.Now())
if result == nil {
t.Fatal("expected non-nil result")
}
if !result.HasNVMe {
t.Error("expected HasNVMe to be true")
}
if len(result.NVMe) != 2 {
t.Errorf("expected 2 NVMe devices, got %d", len(result.NVMe))
}
// NVMe should be sorted
if result.NVMe[0].Device != "nvme0" || result.NVMe[1].Device != "nvme1" {
t.Error("NVMe devices not sorted correctly")
}
}
func TestConvertHostSensorsToTemperature_GPU(t *testing.T) {
sensors := models.HostSensorSummary{
TemperatureCelsius: map[string]float64{
"cpu_package": 45.0,
"gpu_edge": 60.0,
"gpu_junction": 65.0,
"gpu_mem": 55.0,
},
}
result := convertHostSensorsToTemperature(sensors, time.Now())
if result == nil {
t.Fatal("expected non-nil result")
}
if !result.HasGPU {
t.Error("expected HasGPU to be true")
}
if len(result.GPU) != 1 {
t.Errorf("expected 1 GPU, got %d", len(result.GPU))
}
if result.GPU[0].Device != "gpu0" {
t.Errorf("expected device 'gpu0', got %q", result.GPU[0].Device)
}
if result.GPU[0].Edge != 60.0 {
t.Errorf("expected Edge 60.0, got %f", result.GPU[0].Edge)
}
if result.GPU[0].Junction != 65.0 {
t.Errorf("expected Junction 65.0, got %f", result.GPU[0].Junction)
}
}
func TestConvertHostSensorsToTemperature_GenericGPU(t *testing.T) {
sensors := models.HostSensorSummary{
TemperatureCelsius: map[string]float64{
"cpu_package": 45.0,
"gpu_nvidia": 70.0,
},
}
result := convertHostSensorsToTemperature(sensors, time.Now())
if result == nil {
t.Fatal("expected non-nil result")
}
if !result.HasGPU {
t.Error("expected HasGPU to be true")
}
if len(result.GPU) != 1 {
t.Errorf("expected 1 GPU, got %d", len(result.GPU))
}
if result.GPU[0].Device != "nvidia" {
t.Errorf("expected device 'nvidia', got %q", result.GPU[0].Device)
}
if result.GPU[0].Edge != 70.0 {
t.Errorf("expected Edge 70.0, got %f", result.GPU[0].Edge)
}
}
func TestConvertHostSensorsToTemperature_NoPackageUsesMaxCore(t *testing.T) {
sensors := models.HostSensorSummary{
TemperatureCelsius: map[string]float64{
"cpu_core_0": 50.0,
"cpu_core_1": 55.0,
},
}
result := convertHostSensorsToTemperature(sensors, time.Now())
if result == nil {
t.Fatal("expected non-nil result")
}
// When no package temp, CPUPackage should use max core temp
if result.CPUPackage != 55.0 {
t.Errorf("expected CPUPackage to be max core temp 55.0, got %f", result.CPUPackage)
}
}
func TestShouldSkipTemperatureSSHCollection(t *testing.T) {
t.Run("nil host agent temp does not skip", func(t *testing.T) {
if shouldSkipTemperatureSSHCollection(nil) {
t.Fatal("expected nil host agent temp not to skip SSH collection")
}
})
t.Run("host agent temp without recent timestamp does not skip", func(t *testing.T) {
host := &models.Temperature{
Available: true,
HasCPU: true,
CPUPackage: 55,
}
if shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected CPU-only host agent temp without a recent timestamp not to skip SSH collection")
}
})
t.Run("recent cpu package host agent temp skips", func(t *testing.T) {
host := &models.Temperature{
Available: true,
HasCPU: true,
CPUPackage: 55,
LastUpdate: time.Now(),
}
if !shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected recent CPU host agent temp to skip legacy SSH collection")
}
})
t.Run("recent cpu core host agent temp skips", func(t *testing.T) {
host := &models.Temperature{
Available: true,
HasCPU: true,
Cores: []models.CoreTemp{{Core: 0, Temp: 51}},
LastUpdate: time.Now(),
}
if !shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected recent CPU core host agent temp to skip legacy SSH collection")
}
})
t.Run("recent nvme host agent temp skips", func(t *testing.T) {
host := &models.Temperature{
Available: true,
HasNVMe: true,
NVMe: []models.NVMeTemp{{Device: "nvme0", Temp: 42}},
LastUpdate: time.Now(),
}
if !shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected recent NVMe host agent temp to skip legacy SSH collection")
}
})
t.Run("recent gpu host agent temp skips", func(t *testing.T) {
host := &models.Temperature{
Available: true,
HasGPU: true,
GPU: []models.GPUTemp{{Device: "gpu0", Edge: 62}},
LastUpdate: time.Now(),
}
if !shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected recent GPU host agent temp to skip legacy SSH collection")
}
})
t.Run("stale cpu only host agent temp does not skip", func(t *testing.T) {
host := &models.Temperature{
Available: true,
HasCPU: true,
CPUPackage: 55,
LastUpdate: time.Now().Add(-3 * time.Minute),
}
if shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected stale CPU-only host agent temp not to skip SSH collection")
}
})
t.Run("unavailable host agent temp does not skip", func(t *testing.T) {
host := &models.Temperature{
Available: false,
HasCPU: true,
CPUPackage: 55,
LastUpdate: time.Now(),
}
if shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected unavailable host agent temp not to skip SSH collection")
}
})
t.Run("host agent smart data skips", func(t *testing.T) {
host := &models.Temperature{
Available: true,
HasCPU: true,
HasSMART: true,
SMART: []models.DiskTemp{{Device: "/dev/sda", Temperature: 35}},
LastUpdate: time.Now(),
}
if !shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected SMART-capable host agent temp to skip SSH collection")
}
})
t.Run("host agent smart inventory without any temperature does not skip", func(t *testing.T) {
host := &models.Temperature{
Available: true,
HasSMART: true,
SMART: []models.DiskTemp{{Device: "/dev/sda", Temperature: 0}},
LastUpdate: time.Now(),
}
if shouldSkipTemperatureSSHCollection(host) {
t.Fatal("expected identity-only SMART rows without a temperature to allow legacy SSH fallback")
}
})
}
func TestIsHostAgentTemperatureRecent(t *testing.T) {
tests := []struct {
name string
lastSeen time.Time
expected bool
}{
{
name: "recent - just now",
lastSeen: time.Now(),
expected: true,
},
{
name: "recent - 1 minute ago",
lastSeen: time.Now().Add(-1 * time.Minute),
expected: true,
},
{
name: "stale - 3 minutes ago",
lastSeen: time.Now().Add(-3 * time.Minute),
expected: false,
},
{
name: "stale - 1 hour ago",
lastSeen: time.Now().Add(-1 * time.Hour),
expected: false,
},
}
for _, tt := range tests {
t.Run(tt.name, func(t *testing.T) {
result := isHostAgentTemperatureRecent(tt.lastSeen)
if result != tt.expected {
t.Errorf("isHostAgentTemperatureRecent() = %v, want %v", result, tt.expected)
}
})
}
}
func TestMergeTemperatureData_NilInputs(t *testing.T) {
t.Run("both nil", func(t *testing.T) {
result := mergeTemperatureData(nil, nil)
if result != nil {
t.Error("expected nil for both nil inputs")
}
})
t.Run("host nil", func(t *testing.T) {
proxy := &models.Temperature{CPUPackage: 50.0}
result := mergeTemperatureData(nil, proxy)
if result != proxy {
t.Error("expected proxy when host is nil")
}
})
t.Run("proxy nil", func(t *testing.T) {
host := &models.Temperature{CPUPackage: 55.0}
result := mergeTemperatureData(host, nil)
if result != host {
t.Error("expected host when proxy is nil")
}
})
}
func TestMergeTemperatureData_PreservesLegacySensorsFormat(t *testing.T) {
hostTemp := &models.Temperature{
CPUPackage: 55.0,
HasCPU: true,
Available: true,
LastUpdate: time.Now(),
}
proxyTemp := &models.Temperature{
CPUPackage: 52.0,
HasCPU: true,
Available: true,
LegacySensorsFormat: true,
}
result := mergeTemperatureData(hostTemp, proxyTemp)
if result == nil {
t.Fatal("expected non-nil result")
}
if !result.LegacySensorsFormat {
t.Error("expected LegacySensorsFormat from proxy to survive the merge")
}
}
func TestMergeTemperatureData_Merge(t *testing.T) {
hostTemp := &models.Temperature{
CPUPackage: 55.0,
CPUMax: 55.0,
HasCPU: true,
Cores: []models.CoreTemp{
{Core: 0, Temp: 50.0},
{Core: 1, Temp: 55.0},
},
LastUpdate: time.Now(),
}
proxyTemp := &models.Temperature{
CPUPackage: 52.0,
CPUMin: 30.0,
CPUMaxRecord: 60.0,
HasCPU: true,
HasSMART: true,
SMART: []models.DiskTemp{
{Device: "/dev/sda", Temperature: 35},
},
}
result := mergeTemperatureData(hostTemp, proxyTemp)
if result == nil {
t.Fatal("expected non-nil result")
}
// Host agent CPU takes priority
if result.CPUPackage != 55.0 {
t.Errorf("expected CPUPackage 55.0 from host, got %f", result.CPUPackage)
}
// Proxy historical data preserved
if result.CPUMin != 30.0 {
t.Errorf("expected CPUMin 30.0 from proxy, got %f", result.CPUMin)
}
// SMART data from proxy preserved
if !result.HasSMART {
t.Error("expected HasSMART to be true")
}
if len(result.SMART) != 1 {
t.Errorf("expected 1 SMART disk, got %d", len(result.SMART))
}
}
func TestMergeTemperatureData_FallbackToProxy(t *testing.T) {
// Host has no CPU data, should fall back to proxy
hostTemp := &models.Temperature{
HasGPU: true,
GPU: []models.GPUTemp{
{Device: "gpu0", Edge: 70.0},
},
LastUpdate: time.Now(),
}
proxyTemp := &models.Temperature{
CPUPackage: 52.0,
CPUMax: 52.0,
HasCPU: true,
Cores: []models.CoreTemp{
{Core: 0, Temp: 48.0},
},
}
result := mergeTemperatureData(hostTemp, proxyTemp)
if result == nil {
t.Fatal("expected non-nil result")
}
// Should fall back to proxy CPU data
if result.CPUPackage != 52.0 {
t.Errorf("expected CPUPackage 52.0 from proxy fallback, got %f", result.CPUPackage)
}
if len(result.Cores) != 1 {
t.Errorf("expected 1 core from proxy, got %d", len(result.Cores))
}
// Host GPU data should be present
if !result.HasGPU {
t.Error("expected HasGPU to be true")
}
if len(result.GPU) != 1 {
t.Errorf("expected 1 GPU from host, got %d", len(result.GPU))
}
}
func TestGetHostAgentTemperature(t *testing.T) {
m := &Monitor{state: models.NewState()}
t.Run("no hosts in state", func(t *testing.T) {
result := m.getHostAgentTemperature("node1")
assert.Nil(t, result)
})
t.Run("match by linked node id", func(t *testing.T) {
host := models.Host{
ID: "host1",
LinkedNodeID: "node-123",
Sensors: models.HostSensorSummary{
TemperatureCelsius: map[string]float64{"cpu_package": 60.0},
},
LastSeen: time.Now(),
}
m.state.UpsertHost(host)
result := m.getHostAgentTemperatureForNode(models.Node{ID: "node-123", Name: "different-name"})
assert.NotNil(t, result)
assert.Equal(t, 60.0, result.CPUPackage)
})
t.Run("match by linked node id with SMART-only sensors", func(t *testing.T) {
host := models.Host{
ID: "host-smart-only",
LinkedNodeID: "node-smart-only",
Sensors: models.HostSensorSummary{
SMART: []models.HostDiskSMART{
{Device: "/dev/sda", Temperature: 36, Health: "PASSED"},
},
},
LastSeen: time.Now(),
}
m.state.UpsertHost(host)
result := m.getHostAgentTemperatureForNode(models.Node{ID: "node-smart-only", Name: "different-name"})
assert.NotNil(t, result)
assert.True(t, result.Available)
assert.True(t, result.HasSMART)
if assert.Len(t, result.SMART, 1) {
assert.Equal(t, "/dev/sda", result.SMART[0].Device)
assert.Equal(t, 36, result.SMART[0].Temperature)
}
})
t.Run("match by hostname fallback", func(t *testing.T) {
host := models.Host{
ID: "host2",
Hostname: "node2",
Sensors: models.HostSensorSummary{
TemperatureCelsius: map[string]float64{"cpu_package": 65.0},
},
LastSeen: time.Now(),
}
m.state.UpsertHost(host)
result := m.getHostAgentTemperature("node2")
assert.NotNil(t, result)
assert.Equal(t, 65.0, result.CPUPackage)
})
t.Run("no matching host", func(t *testing.T) {
result := m.getHostAgentTemperature("node-missing")
assert.Nil(t, result)
})
t.Run("matching host but no sensor data", func(t *testing.T) {
host := models.Host{
ID: "host3",
Hostname: "node3",
}
m.state.UpsertHost(host)
result := m.getHostAgentTemperature("node3")
assert.Nil(t, result)
})
}
func TestConvertHostSensorsToTemperature_ExtraBranches(t *testing.T) {
t.Run("SMART disk standby", func(t *testing.T) {
sensors := models.HostSensorSummary{
TemperatureCelsius: map[string]float64{"cpu_package": 45.0},
SMART: []models.HostDiskSMART{
{Device: "/dev/sda [sat]", Temperature: 35, Standby: false},
{Device: "sdb", Temperature: 0, Standby: true},
},
}
result := convertHostSensorsToTemperature(sensors, time.Now())
assert.NotNil(t, result)
assert.Len(t, result.SMART, 1)
assert.Equal(t, "/dev/sda", result.SMART[0].Device)
})
t.Run("SMART-only sensors stay available", func(t *testing.T) {
sensors := models.HostSensorSummary{
SMART: []models.HostDiskSMART{
{Device: "/dev/sdc", Temperature: 37},
},
}
result := convertHostSensorsToTemperature(sensors, time.Now())
assert.NotNil(t, result)
assert.True(t, result.Available)
assert.True(t, result.HasSMART)
if assert.Len(t, result.SMART, 1) {
assert.Equal(t, "/dev/sdc", result.SMART[0].Device)
assert.Equal(t, 37, result.SMART[0].Temperature)
}
})
t.Run("GPU merge into same device", func(t *testing.T) {
sensors := models.HostSensorSummary{
TemperatureCelsius: map[string]float64{
"gpu_edge": 60.0,
"gpu_junction": 65.0,
},
}
result := convertHostSensorsToTemperature(sensors, time.Now())
assert.NotNil(t, result)
assert.Len(t, result.GPU, 1)
assert.Equal(t, "gpu0", result.GPU[0].Device)
assert.Equal(t, 60.0, result.GPU[0].Edge)
assert.Equal(t, 65.0, result.GPU[0].Junction)
})
}
// readStateMonitor returns a monitor whose unified read state is the registry
// projection of nodes and hosts, as the poller sees it. Nodes are linked back to
// the hosts linked to them, as the agent linker leaves them.
func readStateMonitor(nodes []models.Node, hosts []models.Host) *Monitor {
for i := range nodes {
for _, host := range hosts {
if host.LinkedNodeID == nodes[i].ID {
nodes[i].LinkedAgentID = host.ID
}
}
}
adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
adapter.PopulateFromSnapshot(models.StateSnapshot{Nodes: nodes, Hosts: hosts})
return &Monitor{
state: models.NewState(),
resourceStore: adapter,
clusterSensorsCache: make(map[string]clusterSensorsCacheEntry),
}
}
func readStateTestNode(instance, name string) models.Node {
return models.Node{ID: instance + "-" + name, Instance: instance, Name: name, Status: "online", LastSeen: time.Now()}
}
func reportingTestHost(id, hostname, linkedNodeID string, cpuPackage float64) models.Host {
host := models.Host{ID: id, Hostname: hostname, Status: "online", LinkedNodeID: linkedNodeID, IntervalSeconds: 30, LastSeen: time.Now()}
if cpuPackage > 0 {
host.Sensors = models.HostSensorSummary{TemperatureCelsius: map[string]float64{"cpu_package": cpuPackage}}
}
return host
}
func clusterSensorReport(nodeName string, cpuPackage float64) []agentshost.ClusterNodeSensors {
return []agentshost.ClusterNodeSensors{{
NodeName: nodeName,
Sensors: agentshost.Sensors{TemperatureCelsius: map[string]float64{"cpu_package": cpuPackage, "cpu_core_0": cpuPackage - 3}},
}}
}
func TestGetClusterSensorTemperature(t *testing.T) {
m := readStateMonitor(
[]models.Node{readStateTestNode("pve1", "node1"), readStateTestNode("pve1", "node2"), readStateTestNode("pve1", "MyNode"), readStateTestNode("pve1", "stale-node")},
[]models.Host{reportingTestHost("agent-node1", "node1", "pve1-node1", 0), reportingTestHost("agent-unlinked", "elsewhere", "", 0)},
)
lookup := func(nodeID, nodeName string) *models.Temperature {
readState := m.GetUnifiedReadStateOrSnapshot()
polled := models.Node{ID: nodeID, Name: nodeName}
slot := m.polledNodeSlot(readState.Hosts(), readState.Nodes(), polled)
return m.getClusterSensorTemperature(readState.Hosts(), readState.Nodes(), polled, slot)
}
t.Run("empty cache returns nil", func(t *testing.T) {
assert.Nil(t, lookup("pve1-node2", "node2"))
})
t.Run("cached data returned", func(t *testing.T) {
m.applyClusterSensors("agent-node1", clusterSensorReport("node2", 58), time.Now())
result := lookup("pve1-node2", "node2")
if assert.NotNil(t, result) {
assert.Equal(t, 58.0, result.CPUPackage)
assert.True(t, result.HasCPU)
}
})
t.Run("stale data returns nil", func(t *testing.T) {
m.applyClusterSensors("agent-node1", clusterSensorReport("stale-node", 50), time.Now().Add(-3*time.Minute)) // older than 2min threshold
assert.Nil(t, lookup("pve1-stale-node", "stale-node"))
})
t.Run("case insensitive lookup", func(t *testing.T) {
m.applyClusterSensors("agent-node1", clusterSensorReport("mynode", 60), time.Now())
result := lookup("pve1-MyNode", "MyNode")
if assert.NotNil(t, result) {
assert.Equal(t, 60.0, result.CPUPackage)
}
})
t.Run("reading from an unlinked agent serves no node", func(t *testing.T) {
m.applyClusterSensors("agent-unlinked", clusterSensorReport("node1", 40), time.Now())
assert.Nil(t, lookup("pve1-node1", "node1"))
})
t.Run("node of another connection returns nil", func(t *testing.T) {
assert.Nil(t, lookup("", "node2"))
assert.Nil(t, lookup("pve9-node2", "node2"))
})
t.Run("node not yet in the read state is scoped by its own connection", func(t *testing.T) {
m.applyClusterSensors("agent-node1", clusterSensorReport("node9", 47), time.Now())
readState := m.GetUnifiedReadStateOrSnapshot()
polled := readStateTestNode("pve1", "node9")
result := m.getClusterSensorTemperature(readState.Hosts(), readState.Nodes(), polled, m.polledNodeSlot(readState.Hosts(), readState.Nodes(), polled))
if assert.NotNil(t, result) {
assert.Equal(t, 47.0, result.CPUPackage)
}
})
t.Run("empty node name returns nil", func(t *testing.T) {
assert.Nil(t, lookup("pve1-node2", ""))
})
}
func TestGetHostAgentTemperatureByID_ClusterFallback(t *testing.T) {
m := readStateMonitor(
[]models.Node{readStateTestNode("pve1", "sibling"), readStateTestNode("pve1", "orphan-node")},
[]models.Host{reportingTestHost("agent-sibling", "sibling", "pve1-sibling", 0)},
)
// No host agent on the node, but a sibling's agent collected its sensors
m.applyClusterSensors("agent-sibling", clusterSensorReport("orphan-node", 62), time.Now())
result := m.getHostAgentTemperatureForNode(models.Node{ID: "pve1-orphan-node", Name: "orphan-node"})
if assert.NotNil(t, result, "should fall back to cluster sensor cache") {
assert.Equal(t, 62.0, result.CPUPackage)
}
}
func TestGetHostAgentTemperatureByID_LocalAgentTakesPriority(t *testing.T) {
m := readStateMonitor(
[]models.Node{readStateTestNode("pve1", "sibling"), readStateTestNode("pve1", "shared-node")},
[]models.Host{
reportingTestHost("agent-sibling", "sibling", "pve1-sibling", 0),
reportingTestHost("host-local", "shared-node", "pve1-shared-node", 70), // local agent reports 70
},
)
// Both the local agent and the cluster cache have data for the same node
m.applyClusterSensors("agent-sibling", clusterSensorReport("shared-node", 55), time.Now()) // cluster cache says 55
result := m.getHostAgentTemperatureForNode(models.Node{ID: "pve1-shared-node", Name: "shared-node"})
if assert.NotNil(t, result) {
assert.Equal(t, 70.0, result.CPUPackage, "local agent data should take priority over cluster cache")
}
}
// An agent that stops reporting keeps its last sensors in state. Past the
// reporting lease that marks it offline, those sensors must not keep feeding the
// linked node as a live reading; the cluster cache (with its own recency) is
// still consulted.
func TestGetHostAgentTemperatureByID_IgnoresAgentPastReportingLease(t *testing.T) {
nodes := []models.Node{readStateTestNode("pve1", "silent-node"), readStateTestNode("pve1", "sibling")}
sibling := reportingTestHost("agent-sibling", "sibling", "pve1-sibling", 0)
silent := reportingTestHost("host-silent", "silent-node", "pve1-silent-node", 95)
silent.LastSeen = time.Now().Add(-hostAgentHealthWindow(30) - time.Minute)
m := readStateMonitor(nodes, []models.Host{silent, sibling})
assert.Nil(t, m.getHostAgentTemperatureForNode(models.Node{ID: "pve1-silent-node", Name: "silent-node"}),
"a silent agent's retained sensors must not be presented as a current reading")
m.applyClusterSensors("agent-sibling", clusterSensorReport("silent-node", 58), time.Now())
if result := m.getHostAgentTemperatureForNode(models.Node{ID: "pve1-silent-node", Name: "silent-node"}); assert.NotNil(t, result) {
assert.Equal(t, 58.0, result.CPUPackage, "a recent cluster-cache reading still serves the node")
}
reporting := reportingTestHost("host-silent", "silent-node", "pve1-silent-node", 71)
m.resourceStore.(*unifiedresources.MonitorAdapter).PopulateFromSnapshot(models.StateSnapshot{Nodes: nodes, Hosts: []models.Host{reporting, sibling}})
if result := m.getHostAgentTemperatureForNode(models.Node{ID: "pve1-silent-node", Name: "silent-node"}); assert.NotNil(t, result) {
assert.Equal(t, 71.0, result.CPUPackage, "a reporting agent's reading is used again")
}
}
// When every temperature source returns nothing, a previous reading may be
// carried only inside the carry window and keeps its original timestamp; an
// older one is dropped rather than re-presented as current.
func TestCollectNodeTemperatureCarryIsBoundedByCarryWindow(t *testing.T) {
m := &Monitor{
config: &config.Config{TemperatureMonitoringEnabled: true, PVEPollingInterval: 10 * time.Second},
state: models.NewState(),
}
collectWithPrevious := func(prev *models.Temperature) *models.Temperature {
node := models.Node{ID: "pve1-node1", Name: "node1", Instance: "pve1"}
m.collectNodeTemperatureData(
context.Background(), "pve1", &config.PVEInstance{Name: "pve1"}, proxmox.Node{Node: "node1"},
&node, []models.Node{{ID: node.ID, Temperature: prev}}, "online",
)
return node.Temperature
}
assert.Equal(t, 5*time.Minute, m.nodeTemperatureCarryWindow(), "the floor applies at the default polling interval")
m.config.PVEPollingInterval = 10 * time.Minute
assert.Equal(t, 20*time.Minute, m.nodeTemperatureCarryWindow(), "the window scales with a slow polling interval")
m.config.PVEPollingInterval = 10 * time.Second
recent := time.Now().Add(-time.Minute)
if carried := collectWithPrevious(&models.Temperature{Available: true, CPUPackage: 92, LastUpdate: recent}); assert.NotNil(t, carried) {
assert.True(t, carried.Available)
assert.True(t, carried.LastUpdate.Equal(recent), "a carried reading keeps its original timestamp")
}
stale := time.Now().Add(-m.nodeTemperatureCarryWindow() - time.Minute)
assert.Nil(t, collectWithPrevious(&models.Temperature{Available: true, CPUPackage: 92, LastUpdate: stale}),
"a reading older than the carry window must not be presented as current")
assert.Nil(t, collectWithPrevious(&models.Temperature{Available: true, CPUPackage: 92}),
"a reading with no timestamp cannot be shown to be recent")
}
func TestHostAgentReportCurrent(t *testing.T) {
now := time.Now()
assert.False(t, hostAgentReportCurrent(time.Time{}, 30, now), "an agent that never reported has no current reading")
assert.True(t, hostAgentReportCurrent(now.Add(-hostAgentHealthWindow(30)), 30, now))
assert.False(t, hostAgentReportCurrent(now.Add(-hostAgentHealthWindow(30)-time.Second), 30, now))
// A slow agent's lease scales with its declared interval.
assert.True(t, hostAgentReportCurrent(now.Add(-8*time.Minute), 120, now))
}
func TestGetHostAgentTemperatureByID_UsesUnifiedReadState(t *testing.T) {
now := time.Now().UTC()
registry := unifiedresources.NewRegistry(nil)
registry.IngestSnapshot(models.StateSnapshot{
Hosts: []models.Host{
{
ID: "host-readstate",
Hostname: "readstate-node",
LinkedNodeID: "node-readstate",
LastSeen: now,
Sensors: models.HostSensorSummary{
TemperatureCelsius: map[string]float64{
"cpu_package": 71.0,
},
SMART: []models.HostDiskSMART{
{Device: "sda", Temperature: 35, Standby: true},
{Device: "sdb", Temperature: 37},
},
},
},
},
})
m := &Monitor{
state: models.NewState(),
resourceStore: unifiedresources.NewMonitorAdapter(registry),
}
result := m.getHostAgentTemperatureForNode(models.Node{ID: "node-readstate", Name: "ignored"})
assert.NotNil(t, result)
assert.Equal(t, 71.0, result.CPUPackage)
if assert.Len(t, result.SMART, 1) {
assert.Equal(t, "/dev/sdb", result.SMART[0].Device)
}
}
func TestMergeTemperatureData_HistoricalOverrides(t *testing.T) {
t.Run("historical max update", func(t *testing.T) {
host := &models.Temperature{CPUPackage: 70.0, HasCPU: true, Available: true}
proxy := &models.Temperature{CPUPackage: 50.0, CPUMaxRecord: 60.0, HasCPU: true}
result := mergeTemperatureData(host, proxy)
assert.Equal(t, 70.0, result.CPUMaxRecord)
})
t.Run("fallback to proxy GPU and NVMe", func(t *testing.T) {
host := &models.Temperature{CPUPackage: 50.0, HasCPU: true}
proxy := &models.Temperature{
HasGPU: true,
GPU: []models.GPUTemp{{Device: "gpu0", Edge: 55.0}},
HasNVMe: true,
NVMe: []models.NVMeTemp{{Device: "nvme0", Temp: 40.0}},
}
result := mergeTemperatureData(host, proxy)
assert.True(t, result.HasGPU)
assert.True(t, result.HasNVMe)
assert.Len(t, result.GPU, 1)
assert.Len(t, result.NVMe, 1)
})
t.Run("proxy SMART temperatures replace host inventory rows", func(t *testing.T) {
host := &models.Temperature{
CPUPackage: 50.0,
HasCPU: true,
HasSMART: true,
SMART: []models.DiskTemp{{Device: "/dev/sda", Temperature: 0}},
}
proxy := &models.Temperature{
HasSMART: true,
SMART: []models.DiskTemp{{Device: "/dev/sda", Temperature: 39}},
}
result := mergeTemperatureData(host, proxy)
assert.True(t, result.HasSMART)
if assert.Len(t, result.SMART, 1) {
assert.Equal(t, 39, result.SMART[0].Temperature)
}
})
}
// The CPU record follows the primary reading, so the drawer's record row is
// never below its headline, and a raised record carries its time.
func TestMergeTemperatureData_RecordFollowsPrimaryReading(t *testing.T) {
recordedBefore := time.Now().Add(-time.Hour)
host := &models.Temperature{
CPUPackage: 60,
CPUMax: 66,
Cores: []models.CoreTemp{{Core: 0, Temp: 66}},
HasCPU: true,
Available: true,
}
proxy := &models.Temperature{CPUMaxRecord: 62, MaxRecorded: recordedBefore, HasCPU: true}
result := mergeTemperatureData(host, proxy)
assert.Equal(t, 66.0, result.CPUMaxRecord)
assert.True(t, result.MaxRecorded.After(recordedBefore), "raised record must carry its time")
}