Files
Pulse/internal/monitoring/host_agent_temps.go
rcourtman 4f14ad6ab9 Use one primary CPU temperature rule everywhere
Three rules chose a node's single CPU temperature. Node history took
CPUMax first, agent history took cpu_package first, and the node drawer
recomputed the maximum of package, CPUMax and every core in the
browser. On an agent-fed node CPUMax is built from cores alone and can
sit below the package, and elsewhere a core can run above the package,
so the drawer's CPU temperature headline could disagree with the line
drawn beneath it and with the History tab. Node alerts and the CPU
low/record tracking used yet another package-first rule.

models.PrimaryCPUTemperatureCelsius is now the one rule: the hottest
usable package, CPU-maximum or core reading, with a sensor-map form for
agents. Node and agent history, the router's live fallbacks, the
unified resource temperature, node temperature alerts and the CPU
low/record tracking all call it. The drawer reads the resource value
through a new Node.cpuTemperature field instead of recomputing it, and
getCpuTemperature is removed.

Mock mode wrote a second package reading under a cpu.package key into
every agent host, including node-linked ones, from a series unrelated
to the node's static reading. A node and its linked agent now carry one
reading, sampled from the agent's series under the agent's real keys,
and both histories seed from that series, so the current reading
continues the line.
2026-10-13 20:15:36 +01:00

733 lines
24 KiB
Go

package monitoring
import (
"regexp"
"slices"
"sort"
"strconv"
"strings"
"time"
"github.com/rcourtman/pulse-go-rewrite/internal/models"
"github.com/rcourtman/pulse-go-rewrite/internal/unifiedresources"
"github.com/rs/zerolog/log"
)
// getHostAgentTemperature looks for a matching host agent and converts
// its sensor data to the Temperature model used by Proxmox nodes.
// It first tries to match by nodeID using the LinkedNodeID field (preferred for
// duplicate hostname scenarios), then falls back to hostname matching.
// Returns nil if no matching host agent is found or if no temperature data is available.
func (m *Monitor) getHostAgentTemperature(nodeName string) *models.Temperature {
return m.getHostAgentTemperatureForNode(models.Node{Name: nodeName})
}
func shouldSkipTemperatureSSHCollection(hostAgentTemp *models.Temperature) bool {
if hostAgentTemp == nil {
return false
}
if !hostAgentTemp.Available || !isHostAgentTemperatureRecent(hostAgentTemp.LastUpdate) {
return false
}
return hasUsableTemperatureReading(hostAgentTemp)
}
func hasUsableTemperatureReading(temp *models.Temperature) bool {
if temp == nil {
return false
}
if temp.CPUPackage > 0 || temp.CPUMax > 0 {
return true
}
for _, core := range temp.Cores {
if core.Temp > 0 {
return true
}
}
for _, device := range temp.NVMe {
if device.Temp > 0 {
return true
}
}
for _, gpu := range temp.GPU {
if gpu.Edge > 0 || gpu.Junction > 0 || gpu.Mem > 0 {
return true
}
}
return hasUsableSMARTTemperature(temp)
}
func hasUsableSMARTTemperature(temp *models.Temperature) bool {
if temp == nil || !temp.HasSMART {
return false
}
for _, disk := range temp.SMART {
if disk.Temperature > 0 && !disk.StandbySkipped {
return true
}
}
return false
}
// getHostAgentTemperatureForNode returns a polled Proxmox node's reading from
// its host agent (see hostAgentForNode), else from a sibling agent's cluster
// sensor cache. node is the poller's model of the node: its source ID, native
// name, connection and identity stamps.
func (m *Monitor) getHostAgentTemperatureForNode(node models.Node) *models.Temperature {
readState := m.GetUnifiedReadStateOrSnapshot()
if readState == nil {
return nil
}
hosts := readState.Hosts()
nodes := readState.Nodes()
slot := m.polledNodeSlot(hosts, nodes, node)
matchedHost := hostAgentForNode(hosts, nodes, slot, node.Name, m.nodeAgentSplitFilter(node))
if matchedHost == nil {
// No directly-linked host agent found — check cluster sensor cache
return m.getClusterSensorTemperature(hosts, nodes, node, slot)
}
// Check if the host agent has temperature data. SMART-only reports are
// valid here: some PVE nodes expose no CPU sensor chip but still provide
// disk temperatures through the local agent.
sensors := matchedHost.Sensors()
if sensors == nil || (len(sensors.TemperatureCelsius) == 0 && len(sensors.SMART) == 0) {
// Host agent exists but has no temperature data — try cluster cache
return m.getClusterSensorTemperature(hosts, nodes, node, slot)
}
// An agent that stopped reporting keeps its last sensors in state. Those
// describe the machine as it was, so they must not keep feeding the node
// (and through it alerts and history) as a live reading. The row's own
// LastSeen cannot tell: a row merged with the Proxmox node stays fresh from
// every PVE poll, so read the agent source's sighting.
agentStatus, ok := matchedHost.SourceStatus(unifiedresources.SourceAgent)
if !ok || !hostAgentReportCurrent(agentStatus.LastSeen, matchedHost.IntervalSeconds(), time.Now()) {
return m.getClusterSensorTemperature(hosts, nodes, node, slot)
}
// Convert host agent sensor data to Temperature model, stamped with the
// agent's report time rather than the merged row's.
return convertUnifiedHostSensorsToTemperature(sensors, agentStatus.LastSeen)
}
// carriedTemperatureOutlivesAgentLease reports whether a temperature a node
// carries over from an earlier poll may have come from the node's host agent
// after that agent stopped reporting. Agent readings are stamped with the
// agent's report time and only count inside its reporting lease, so a reading
// stamped no later than a lapsed agent's last report is treated as the agent's
// and is not carried. Readings carry no source, so an SSH or cluster-cache
// reading of that age is dropped too; it is already older than the lease, and
// the bound errs toward a gap rather than a stale value. A reading stamped
// after that report keeps the ordinary carry window.
func (m *Monitor) carriedTemperatureOutlivesAgentLease(node models.Node, temp *models.Temperature, now time.Time) bool {
if temp == nil {
return false
}
readState := m.GetUnifiedReadStateOrSnapshot()
if readState == nil {
return false
}
hosts := readState.Hosts()
nodes := readState.Nodes()
// A split agent still counts here: the check asks whether a carried
// reading may have been the agent's, and one it supplied before the split
// must not outlive the agent's lease.
matchedHost := hostAgentForNode(hosts, nodes, m.polledNodeSlot(hosts, nodes, node), node.Name, nil)
if matchedHost == nil {
return false
}
agentStatus, ok := matchedHost.SourceStatus(unifiedresources.SourceAgent)
if !ok || agentStatus.LastSeen.IsZero() ||
hostAgentReportCurrent(agentStatus.LastSeen, matchedHost.IntervalSeconds(), now) {
return false
}
return !temp.LastUpdate.After(agentStatus.LastSeen)
}
// nodeSlot is the read-state identity of one polled Proxmox node: the source
// node IDs and connections that denote it.
type nodeSlot struct {
ids []string
instances []string
}
func (s *nodeSlot) add(id, instance string) {
if id = strings.TrimSpace(id); id != "" && !s.hasID(id) {
s.ids = append(s.ids, id)
}
if instance = strings.TrimSpace(instance); instance != "" && !s.hasInstance(instance) {
s.instances = append(s.instances, instance)
}
}
func (s nodeSlot) hasID(id string) bool {
return id != "" && slices.Contains(s.ids, id)
}
func (s nodeSlot) hasInstance(instance string) bool {
return instance != "" && slices.Contains(s.instances, instance)
}
// polledNodeSlot returns the read-state identity of a polled Proxmox node. A
// node the read state holds under its own source ID is that node alone. The
// state folds the views of one machine reached through two connections (a
// cluster added twice, or a multi-homed host added by each address) into one
// slot, kept under whichever view its merge preference keeps, so a polled view
// the read state does not hold also counts as the one same-named node proven to
// be that machine: by models.NodeObservationsSameMachine, or by
// models.HostAgentBridgesNodeViews for the agent linked to that node. Two or
// more such candidates are ambiguous and none is taken, as the state's alias
// resolution declines them. Agent links and cluster-sensor scope are matched
// against the slot, never against a same-named node of another machine.
func (m *Monitor) polledNodeSlot(hosts []*unifiedresources.HostView, nodes []*unifiedresources.NodeView, node models.Node) nodeSlot {
var slot nodeSlot
if strings.TrimSpace(node.ID) == "" {
return slot
}
for _, view := range nodes {
if view != nil && view.SourceID() == node.ID {
slot.add(node.ID, firstNonEmptyString(node.Instance, view.Instance()))
return slot
}
}
slot.add(node.ID, node.Instance)
var partner *unifiedresources.NodeView
for _, view := range nodes {
if view == nil || !strings.EqualFold(view.NodeName(), node.Name) {
continue
}
if !m.nodeViewIsSameMachine(hosts, view, node) {
continue
}
if partner != nil {
return slot
}
partner = view
}
if partner != nil {
slot.add(partner.SourceID(), partner.Instance())
}
return slot
}
// nodeViewIsSameMachine reports whether a read-state Proxmox node and a polled
// node are one machine by the evidence the state folds node views on.
func (m *Monitor) nodeViewIsSameMachine(hosts []*unifiedresources.HostView, view *unifiedresources.NodeView, node models.Node) bool {
stateNode := m.stateNodeFromView(view)
if models.NodeObservationsSameMachine(stateNode, node) {
return true
}
for _, host := range hosts {
if host.LinkedNodeID() == stateNode.ID {
return models.HostAgentBridgesNodeViews(hostFromReadStateView(host), stateNode, node)
}
}
return false
}
// nodeHasProvenViewInConnection reports whether a polled node has a view under
// another Proxmox connection that is the same machine: a cluster added through
// two connections lists the same members, each with its TLS fingerprint, so
// that connection's view of the node's name is the polled node.
func (m *Monitor) nodeHasProvenViewInConnection(node models.Node, instance string) bool {
instanceCfg := m.getInstanceConfig(instance)
if instanceCfg == nil || !instanceCfg.IsCluster {
return false
}
fingerprint := pveNodeTLSFingerprint(instanceCfg, node.Name)
if fingerprint == "" {
return false
}
return models.NodeObservationsSameMachine(models.Node{
Name: node.Name,
Instance: instanceCfg.Name,
ClusterName: instanceCfg.ClusterName,
IsClusterMember: true,
TLSFingerprint: fingerprint,
}, node)
}
// stateNodeFromView restores the identity a read-state Proxmox node carries in
// state, including the config-derived TLS fingerprint the registry does not
// keep, the way previousNodesForInstance does.
func (m *Monitor) stateNodeFromView(view *unifiedresources.NodeView) models.Node {
node := previousNodeFromView(view)
node.TLSFingerprint = pveNodeTLSFingerprint(m.getInstanceConfig(node.Instance), node.Name)
return node
}
// hostAgentForNode returns the host agent for a polled Proxmox node: the agent
// linked to the node's slot, else the one unlinked agent whose hostname is the
// node's name. Several connections can each have a node with the same name
// (one "px1" per site), so the hostname fallback never takes an agent linked to
// another node or to a guest, and finds nothing when a Proxmox node outside the
// slot or a second unlinked agent has the name. Every link source (automatic,
// manual, restored from continuity) stores the Proxmox source node ID, so slot
// IDs compare with LinkedNodeID directly. The hostname fallback also
// skips an agent the operator split from the node (split, which may be nil):
// the split holds the link back, which would otherwise leave the agent
// "unlinked" and let its name hand the node the machine's sensors.
func hostAgentForNode(hosts []*unifiedresources.HostView, nodes []*unifiedresources.NodeView, slot nodeSlot, nodeName string, split func(*unifiedresources.HostView) bool) *unifiedresources.HostView {
for _, host := range hosts {
if slot.hasID(host.LinkedNodeID()) {
log.Debug().
Str("nodeID", host.LinkedNodeID()).
Str("hostAgentID", host.ID()).
Str("hostname", host.Hostname()).
Msg("Matched host agent to node via LinkedNodeID")
return host
}
}
// Fallback for an agent that is not linked yet.
name := strings.ToLower(strings.TrimSpace(nodeName))
if name == "" || otherProxmoxNodeHasName(nodes, slot, name) {
return nil
}
var match *unifiedresources.HostView
for _, host := range hosts {
if host.LinkedNodeID() != "" || host.LinkedVMID() != "" || host.LinkedContainerID() != "" {
continue
}
if strings.ToLower(strings.TrimSpace(host.Hostname())) != name {
continue
}
if split != nil && split(host) {
continue
}
if match != nil {
return nil
}
match = host
}
return match
}
// otherProxmoxNodeHasName reports whether a Proxmox node outside slot is named
// name (lowercase). With an empty slot every node of that name counts.
func otherProxmoxNodeHasName(nodes []*unifiedresources.NodeView, slot nodeSlot, name string) bool {
for _, node := range nodes {
if node == nil || slot.hasID(node.SourceID()) {
continue
}
if strings.ToLower(node.NodeName()) == name {
return true
}
}
return false
}
// proxmoxNodeInstance returns the Proxmox connection a node belongs to, or ""
// when the node is not in the read state.
func proxmoxNodeInstance(nodes []*unifiedresources.NodeView, nodeID string) string {
if nodeID == "" {
return ""
}
for _, node := range nodes {
if node != nil && node.SourceID() == nodeID {
return node.Instance()
}
}
return ""
}
func convertUnifiedHostSensorsToTemperature(sensors *unifiedresources.HostSensorMeta, lastSeen time.Time) *models.Temperature {
if sensors == nil {
return nil
}
return convertHostSensorsToTemperature(models.HostSensorSummary{
TemperatureCelsius: cloneStringFloatMap(sensors.TemperatureCelsius),
FanRPM: cloneStringFloatMap(sensors.FanRPM),
PowerWatts: cloneStringFloatMap(sensors.PowerWatts),
Additional: cloneStringFloatMap(sensors.Additional),
GPU: convertUnifiedHostGPU(sensors.GPU),
SMART: convertUnifiedHostSMART(sensors.SMART),
}, lastSeen)
}
func convertUnifiedHostGPU(gpus []unifiedresources.HostGPUSensor) []models.HostGPUSensor {
if len(gpus) == 0 {
return nil
}
result := make([]models.HostGPUSensor, len(gpus))
for i, gpu := range gpus {
result[i] = models.HostGPUSensor{
ID: gpu.ID,
Name: gpu.Name,
TemperatureCelsius: cloneFloat64Ptr(gpu.TemperatureCelsius),
UtilizationPercent: cloneFloat64Ptr(gpu.UtilizationPercent),
MemoryUsedBytes: cloneInt64Ptr(gpu.MemoryUsedBytes),
MemoryTotalBytes: cloneInt64Ptr(gpu.MemoryTotalBytes),
}
}
return result
}
func convertUnifiedHostSMART(smart []unifiedresources.HostSMARTMeta) []models.HostDiskSMART {
if len(smart) == 0 {
return nil
}
result := make([]models.HostDiskSMART, len(smart))
for i, disk := range smart {
result[i] = models.HostDiskSMART{
Device: disk.Device,
Model: disk.Model,
Serial: disk.Serial,
WWN: disk.WWN,
Type: disk.Type,
SizeBytes: disk.SizeBytes,
Temperature: disk.Temperature,
Health: disk.Health,
Standby: disk.Standby,
Pool: disk.Pool,
Attributes: cloneSMARTAttributesModel(disk.Attributes),
}
}
return result
}
func cloneSMARTAttributesModel(src *models.SMARTAttributes) *models.SMARTAttributes {
if src == nil {
return nil
}
dest := *src
return &dest
}
// getClusterSensorTemperature returns the reading a host agent on a sibling
// cluster node collected for this node over SSH. Siblings are reported by bare
// node name, which nodes of different connections can share, so a reading only
// serves the node when the node its reporting agent is linked to belongs to one
// of the slot's connections, or to a connection with a proven view of the node
// (a cluster added twice). Readings from an unlinked agent serve no node.
func (m *Monitor) getClusterSensorTemperature(hosts []*unifiedresources.HostView, nodes []*unifiedresources.NodeView, node models.Node, slot nodeSlot) *models.Temperature {
name := strings.ToLower(strings.TrimSpace(node.Name))
if name == "" {
return nil
}
// Reuse the same staleness threshold as direct host agents (2 minutes)
var candidates []clusterSensorsCacheEntry
m.clusterSensorsMu.RLock()
for _, entry := range m.clusterSensorsCache {
if entry.nodeName == name && isHostAgentTemperatureRecent(entry.updatedAt) {
candidates = append(candidates, entry)
}
}
m.clusterSensorsMu.RUnlock()
var newest *clusterSensorsCacheEntry
for i := range candidates {
reporterInstance := proxmoxNodeInstance(nodes, linkedNodeIDForAgent(hosts, candidates[i].reporterID))
if reporterInstance == "" ||
(!slot.hasInstance(reporterInstance) && !m.nodeHasProvenViewInConnection(node, reporterInstance)) {
continue
}
if newest == nil || candidates[i].updatedAt.After(newest.updatedAt) {
newest = &candidates[i]
}
}
if newest == nil {
return nil
}
return convertHostSensorsToTemperature(newest.sensors, newest.updatedAt)
}
// linkedNodeIDForAgent returns the Proxmox source node ID the agent with the
// given agent ID (models.Host.ID) is linked to, or "".
func linkedNodeIDForAgent(hosts []*unifiedresources.HostView, agentID string) string {
if agentID == "" {
return ""
}
for _, host := range hosts {
if host.AgentID() == agentID {
return host.LinkedNodeID()
}
}
return ""
}
// convertHostSensorsToTemperature converts HostSensorSummary to the Temperature model.
// The host agent reports temperatures in a flat map with keys like:
// - "cpu_package" -> CPU package temperature
// - "cpu_core_0", "cpu_core_1", etc. -> individual core temperatures
// - "nvme0", "nvme1", etc. -> NVMe temperatures
// - "gpu_edge", "gpu_junction", etc. -> GPU temperatures
func convertHostSensorsToTemperature(sensors models.HostSensorSummary, lastSeen time.Time) *models.Temperature {
if len(sensors.TemperatureCelsius) == 0 && len(sensors.SMART) == 0 {
return nil
}
temp := &models.Temperature{
Available: true,
LastUpdate: lastSeen,
Cores: []models.CoreTemp{},
NVMe: []models.NVMeTemp{},
GPU: []models.GPUTemp{},
}
var coreTemps []float64
corePattern := regexp.MustCompile(`^cpu_core_(\d+)$`)
nvmePattern := regexp.MustCompile(`^(nvme\d+)$`)
gpuPattern := regexp.MustCompile(`^gpu_(.+)$`)
for key, value := range sensors.TemperatureCelsius {
keyLower := strings.ToLower(key)
// CPU package temperature
if keyLower == "cpu_package" {
temp.CPUPackage = value
temp.HasCPU = true
continue
}
// CPU core temperatures
if matches := corePattern.FindStringSubmatch(keyLower); len(matches) == 2 {
coreNum, err := strconv.Atoi(matches[1])
if err == nil {
temp.Cores = append(temp.Cores, models.CoreTemp{
Core: coreNum,
Temp: value,
})
coreTemps = append(coreTemps, value)
temp.HasCPU = true
}
continue
}
// NVMe temperatures
if matches := nvmePattern.FindStringSubmatch(keyLower); len(matches) == 2 {
temp.NVMe = append(temp.NVMe, models.NVMeTemp{
Device: matches[1],
Temp: value,
})
temp.HasNVMe = true
continue
}
// GPU temperatures (gpu_edge, gpu_junction, gpu_mem, or generic gpu_<device>)
if matches := gpuPattern.FindStringSubmatch(keyLower); len(matches) == 2 {
gpuKey := matches[1]
// Handle specific GPU temp types
if gpuKey == "edge" || gpuKey == "junction" || gpuKey == "mem" {
// Find or create GPU entry for the default device
found := false
for i := range temp.GPU {
if temp.GPU[i].Device == "gpu0" {
switch gpuKey {
case "edge":
temp.GPU[i].Edge = value
case "junction":
temp.GPU[i].Junction = value
case "mem":
temp.GPU[i].Mem = value
}
found = true
break
}
}
if !found {
gpu := models.GPUTemp{Device: "gpu0"}
switch gpuKey {
case "edge":
gpu.Edge = value
case "junction":
gpu.Junction = value
case "mem":
gpu.Mem = value
}
temp.GPU = append(temp.GPU, gpu)
}
} else {
// Generic GPU entry with edge temp
temp.GPU = append(temp.GPU, models.GPUTemp{
Device: gpuKey,
Edge: value,
})
}
temp.HasGPU = true
continue
}
}
// Sort cores by core number
sort.Slice(temp.Cores, func(i, j int) bool {
return temp.Cores[i].Core < temp.Cores[j].Core
})
// Sort NVMe by device name
sort.Slice(temp.NVMe, func(i, j int) bool {
return temp.NVMe[i].Device < temp.NVMe[j].Device
})
// Calculate CPUMax from core temperatures if package temp wasn't available
if len(coreTemps) > 0 {
maxTemp := 0.0
for _, t := range coreTemps {
if t > maxTemp {
maxTemp = t
}
}
temp.CPUMax = maxTemp
// If no package temp, use max core temp as package
if temp.CPUPackage == 0 {
temp.CPUPackage = maxTemp
}
}
// Convert S.M.A.R.T. data from host agent
if len(sensors.SMART) > 0 {
temp.SMART = make([]models.DiskTemp, 0, len(sensors.SMART))
for _, disk := range sensors.SMART {
// Skip disks in standby (no temperature data)
if disk.Standby {
continue
}
temp.SMART = append(temp.SMART, models.DiskTemp{
Device: canonicalSMARTDevicePath(disk.Device),
Serial: disk.Serial,
WWN: disk.WWN,
Model: disk.Model,
Type: disk.Type,
Temperature: disk.Temperature,
LastUpdated: lastSeen,
})
}
temp.HasSMART = len(temp.SMART) > 0
}
// Validate we have at least some data
if !temp.HasCPU && !temp.HasGPU && !temp.HasNVMe && !temp.HasSMART {
return nil
}
log.Debug().
Str("source", "agent").
Float64("cpuPackage", temp.CPUPackage).
Float64("cpuMax", temp.CPUMax).
Int("coreCount", len(temp.Cores)).
Int("nvmeCount", len(temp.NVMe)).
Int("gpuCount", len(temp.GPU)).
Int("smartCount", len(temp.SMART)).
Msg("Converted host agent sensors to temperature data")
return temp
}
func canonicalSMARTDevicePath(device string) string {
normalized := normalizeSMARTDeviceIdentifier(device)
if normalized == "" {
return ""
}
return "/dev/" + normalized
}
// isHostAgentTemperatureRecent checks if the host agent temperature data is recent enough to use.
// We consider data stale if the host hasn't reported in more than 2 minutes.
// hostAgentReportCurrent reports whether an agent's last report is still inside
// the reporting lease that keeps the agent online (evaluateHostAgents uses the
// same window), so its sensor readings still describe the machine.
func hostAgentReportCurrent(lastSeen time.Time, intervalSeconds int, now time.Time) bool {
return !lastSeen.IsZero() && now.Sub(lastSeen) <= hostAgentHealthWindow(intervalSeconds)
}
func isHostAgentTemperatureRecent(lastSeen time.Time) bool {
const staleDuration = 2 * time.Minute
return time.Since(lastSeen) < staleDuration
}
// mergeTemperatureData merges host agent temperature with existing/proxy temperature data.
// Host agent data takes priority for CPU temperatures since it's more reliable (no SSH required).
// NVMe/SMART data is merged - host agent NVMe data supplements proxy SMART data.
func mergeTemperatureData(hostAgentTemp, proxyTemp *models.Temperature) *models.Temperature {
if hostAgentTemp == nil {
return proxyTemp
}
if proxyTemp == nil {
return hostAgentTemp
}
// Start with host agent data as base since it's more reliable
result := &models.Temperature{
CPUPackage: hostAgentTemp.CPUPackage,
CPUMax: hostAgentTemp.CPUMax,
CPUMin: proxyTemp.CPUMin, // Preserve historical min
CPUMaxRecord: proxyTemp.CPUMaxRecord, // Raised below from the merged primary reading
MinRecorded: proxyTemp.MinRecorded,
MaxRecorded: proxyTemp.MaxRecorded,
Cores: hostAgentTemp.Cores,
GPU: hostAgentTemp.GPU,
NVMe: hostAgentTemp.NVMe,
Available: true,
HasCPU: hostAgentTemp.HasCPU,
HasGPU: hostAgentTemp.HasGPU,
HasNVMe: hostAgentTemp.HasNVMe,
// The legacy-format marker describes the node's SSH sensor setup; a
// linked host agent doesn't fix that setup, so the flag survives the
// merge (the UI gate hides the notice once disk temps actually arrive).
LegacySensorsFormat: proxyTemp.LegacySensorsFormat,
LastUpdate: hostAgentTemp.LastUpdate,
}
// Use host agent CPU data if available, fall back to proxy
if !hostAgentTemp.HasCPU && proxyTemp.HasCPU {
result.CPUPackage = proxyTemp.CPUPackage
result.CPUMax = proxyTemp.CPUMax
result.Cores = proxyTemp.Cores
result.HasCPU = true
}
// Merge SMART data. Prefer host-agent SMART only when it carries usable
// temperatures; otherwise let the SSH/proxy wrapper fill disk temps and keep
// host-agent SMART inventory only when neither side has temperatures.
switch {
case hasUsableSMARTTemperature(hostAgentTemp):
result.SMART = hostAgentTemp.SMART
case hasUsableSMARTTemperature(proxyTemp):
result.SMART = proxyTemp.SMART
case hostAgentTemp.HasSMART:
result.SMART = hostAgentTemp.SMART
case proxyTemp.HasSMART:
result.SMART = proxyTemp.SMART
}
result.HasSMART = len(result.SMART) > 0
// Merge GPU data - prefer host agent if available
if !hostAgentTemp.HasGPU && proxyTemp.HasGPU {
result.GPU = proxyTemp.GPU
result.HasGPU = true
}
// Merge NVMe data - prefer host agent if available, fall back to proxy
if !hostAgentTemp.HasNVMe && proxyTemp.HasNVMe {
result.NVMe = proxyTemp.NVMe
result.HasNVMe = true
}
// Update historical max if the primary reading is higher
currentTemp := 0.0
if primary := models.PrimaryCPUTemperatureCelsius(result); primary != nil {
currentTemp = *primary
}
if currentTemp > result.CPUMaxRecord {
result.CPUMaxRecord = currentTemp
result.MaxRecorded = time.Now()
}
return result
}